Sharath, PP and Senthil Kumaran, R and Jagannatha Rao, B and Poornima, N (2009) CALIBRATION OF PITOT STATIC PROBES FOR HAL, KORAPUT. Technical Report. National Aerospace Laboratories, Bangalore.
![]() |
PDF
0937.pdf - Submitted Version Download (181kB) |
Abstract
This document furnishes the calibration procedure adopted to test some of the Pitot static probes used by HAL, Koraput in their engine test beds. Twenty eight probes were sent to NAL for calibration and certification. These probes were calibrated in the 254 mm x 102 mm induction wind tunnel at NAL. The probes were calibrated for a Mach number range of 0.1 to 0.4.
Item Type: | Monograph (Technical Report) |
---|---|
Subjects: | AERONAUTICS > Aerodynamics AERONAUTICS > Research and Support Facilities (Air) ENGINEERING > Fluid Mechanics and Thermodynamics PHYSICS |
Depositing User: | Mr R Senthil Kumaran |
Date Deposited: | 05 Aug 2010 07:47 |
Last Modified: | 05 Aug 2010 07:47 |
URI: | http://nal-ir.nal.res.in/id/eprint/8896 |