Rao, DVLN and Venkiteshwaran, SP (1963) Performance of the 6-8 KW Allgaier wind electric generator at porbandar. Technical Report. National Aeronautical Laboratory, Bangalore, India.
![]() |
PDF
tn_wp_33_63_p.36.pdf Restricted to Repository staff only Download (1MB) |
![]() |
Indexer Terms (Generate index codes conversion from application/pdf to indexcodes)
indexcodes.txt Restricted to Repository staff only Download (611B) |
Abstract
The performance of the Allgaier 6-8 kW wind electric generator at a site in the Khapat Agricultural Farm in Porbandar has been examined. The actual electric energy produced a t various wind speeds has been13; compared with the energy calculated on the basis of the power-speed characteristics of the generator, supplied by the manufacturers. Ihe cost of power has also been estimated. The cost per kWh works out to 19 nP. without battery and 45 nP.with battery. The cost of pumping 1,000 gallons of water works out to 12 nP. a s against 35 nP. in the case of a 10 h.p. diesel engine working alongside the wind electric generator,
Item Type: | Monograph (Technical Report) |
---|---|
Uncontrolled Keywords: | Wind electric generator;Wind speeds |
Subjects: | ENGINEERING > Electronics and Electrical Engineering GEOSCIENCES > Meteorology and Climatology |
Depositing User: | M/S ICAST NAL |
Date Deposited: | 19 Jan 2007 |
Last Modified: | 24 May 2010 04:24 |
URI: | http://nal-ir.nal.res.in/id/eprint/3897 |
Actions (login required)
![]() |
View Item |