Sankaranarayanan, S and Ramamurthy, K and Murugesan, K (1985) Performance Evaluation of Centrifugal Compressor Using computer-Aided Testing (CAT) in Clocter Facility. Technical Report. National Aerospace Laboratories, Bangalore, India.
![]() |
PDF
tm_pr_8505_p._35.pdf Restricted to Repository staff only Download (597kB) |
![]() |
Indexer Terms (Generate index codes conversion from application/pdf to indexcodes)
indexcodes.txt Restricted to Repository staff only Download (1kB) |
Abstract
A method to evaluate the performance of a centifugal compressor in the Closed Circuit Centrifugal Compressor Test Rig CLOCTEH, using computer-aided t e s t i n g (CAT), has been reported. I t i n c l u d c s th6 d s t a i l s of complete instrumentation system hooked up to the facility through an on line computer system. Various parameters of the compressor measured in the facility and their nieamrernent accuracies for a typical t e s t case have been pr6Sented. step procedure followed for the computer aided testiny (CAT)of the compressor is explained, The performance A step by characteristic of t h e test compressor t l l u s obtained using this CAT programme is also given.13;
Item Type: | Monograph (Technical Report) |
---|---|
Uncontrolled Keywords: | Centifugal Compressor;Computer Aided Testing. |
Subjects: | AERONAUTICS > Aircraft Propulsion and Power |
Depositing User: | M/S ICAST NAL |
Date Deposited: | 11 Nov 2006 |
Last Modified: | 24 May 2010 04:23 |
URI: | http://nal-ir.nal.res.in/id/eprint/3393 |
Actions (login required)
![]() |
View Item |