Rao, KVL and Sudha, R and Jagannatha Rao, B (1985) A Light Scattering Technique for the Measurement of SMD13; in Sprays. Technical Report. National Aerospace Laboratories, Bangalore, India.
![]() |
PDF
tm_pr_8504_p._38.pdf Restricted to Repository staff only Download (587kB) |
![]() |
Indexer Terms (Generate index codes conversion from application/pdf to indexcodes)
indexcodes.txt Restricted to Repository staff only Download (926B) |
Abstract
A simple and inexpensive opticaltechnique, suitable13; for rapid and accurateevaluation of the SMD of liquid sprays under actual operating environment, has been designed and developed. The design of t h e optical bench i s based o n t h e measurement of angular distribution of the forward scattered light intensity of a manochromatic beam of light passing through aspray , from which the SMD of the spray could be inferreddirectly. The calibration tests have confirmed that the SMD of sprays can be measured toan accuracy of +5% with this optical13; bench, with nashorttime of about 100 sec.
Item Type: | Monograph (Technical Report) |
---|---|
Uncontrolled Keywords: | Drop size;Particle size;Spray mean dropsize;Optical techniques;Measurements;Light scattering. |
Subjects: | AERONAUTICS > Aircraft Propulsion and Power ENGINEERING > Structural Mechanics |
Depositing User: | M/S ICAST NAL |
Date Deposited: | 11 Nov 2006 |
Last Modified: | 13 Aug 2015 07:09 |