X-ray analysis of polycrystalline aluminium subjected to fatigue cycling

Vijayan, Kalyani and Mani, A and Balasingh, C and Singh, AK (1988) X-ray analysis of polycrystalline aluminium subjected to fatigue cycling. Bulletin of Material Science, 10 (3). pp. 205-216.

[img] PDF
bulletin_of_Material_science.pdf

Download (459kB)
[img] Indexer Terms (Generate index codes conversion from application/pdf to indexcodes)
indexcodes.txt

Download (5kB)

Abstract

Variations in the halfwidth values of X-ray reflections from fatigue-cycled, polycrystalline aluminium samples have been analysed. An oscillatory variation of the13; halfwidths with fatigue cycling has been observed. Analysis of the diffraction line profiles indicates that broadening arises mainly because of the build-up of microstrains during fatigue cycling. The present data indicate that (i) broadening due to fatigue cycling increases with glancing angle; (ii) changes in halfwidth and integral widths, due to fatigue cycling, are comparable and (iii) (b/bo) versus N curves for fatigue cycling under constant stress amplitude and flight loading conditions are comparable.

Item Type: Article
Additional Information: Copyright for this article belongs to Indian Academy of 13; Sciences
Uncontrolled Keywords: Aluminium;Fatigue cycling;X-ray diffraction
Subjects: CHEMISTRY AND MATERIALS > Metals and Metallic Materials
Depositing User: Mr. Ravikumar R
Date Deposited: 17 Oct 2006
Last Modified: 24 May 2010 04:21
URI: http://nal-ir.nal.res.in/id/eprint/3051