Mohan, SR and Srinivas, K (1980) Computation of response times of pressure measuring systems employing narrow bore tubing. Technical Report. National Aeronautical Laboratory, Bangalore, India.
![]() |
PDF
tr_ae_tm_13_80.pdf Restricted to Repository staff only Download (714kB) |
![]() |
Indexer Terms (Generate index codes conversion from application/pdf to indexcodes)
indexcodes.txt Restricted to Repository staff only Download (4kB) |
Abstract
Settling Times of pressure measuring systems with narrow bore tubing have been computed for the cases when the input pressure varies suddenly and when the input pressure varies linearly with time. Tubing with non-uniform diameter has also been considered, computations employ methods due to Lilley and Morton and Sato. The methods give almost similar results except for large initial pressure rises when Sato's formulation gives higher values for the settling time. Further, the finite difference schemes employed here are explicit in nature and demand less of computer time and memory compared to that used by Sato,
Item Type: | Monograph (Technical Report) |
---|---|
Uncontrolled Keywords: | Pressure measuring systems;Viscosity;Laminar subsonic flow |
Subjects: | AERONAUTICS > Aerodynamics |
Depositing User: | M/S ICAST NAL |
Date Deposited: | 12 Sep 2006 |
Last Modified: | 24 May 2010 04:20 |
URI: | http://nal-ir.nal.res.in/id/eprint/2688 |
Actions (login required)
![]() |
View Item |