Murthy, Raghu G and Krishnan, A (1988) X-ray tube current regulator. Technical Report. National Aeronautical Laboratory, Bangalore, India.
![]() |
PDF
tr_pdse_8817_R71813_txt.pdf Restricted to Repository staff only Download (4MB) |
![]() |
Indexer Terms (Generate index codes conversion from application/pdf to indexcodes)
indexcodes.txt Restricted to Repository staff only Download (2kB) |
Abstract
Systems Engineering Division has participated in the development of a X -Ray filament current regulator for 13; X - Ray Difractometer of the Material Science Division. The current regulator keeps the plate current constant against the variation in the filament supply voltage and the Plate supply voltage by controlling the filament R.M.S. current. Details of the circuit are presented here.
Item Type: | Monograph (Technical Report) |
---|---|
Uncontrolled Keywords: | X-ray tube current regulator;Filament voltage control |
Subjects: | PHYSICS > Physics(General) |
Depositing User: | Mr. Ravikumar R |
Date Deposited: | 20 Jul 2006 |
Last Modified: | 24 May 2010 04:16 |
URI: | http://nal-ir.nal.res.in/id/eprint/2171 |
Actions (login required)
![]() |
View Item |