Air circulation unit for the 3m Dia x 7m length autoclave -A computer aided design approach

Dayananda, GN and Shankaranarayan, S (1991) Air circulation unit for the 3m Dia x 7m length autoclave -A computer aided design approach. Technical Report. National Aeronautical Laboratory, Bangalore, India.

[img] PDF
tr_pd_st_9108_R84887.pdf
Restricted to Repository staff only

Download (1MB)
[img] Indexer Terms (Generate index codes conversion from application/pdf to indexcodes)
indexcodes.txt
Restricted to Repository staff only

Download (8kB)

Abstract

An Autoclave is an important tool to cure good quality composite components. An efficient Air Circulation System is required to achieve the same . This report aims to improvise the Air. Circulation Unit for the Autoclave . The design approach combines the conventional design and the computer aided techniques . This approach has optimized13; the shaft overhang length and has established good co-relation between the conventional theories and the computer results . This has in turn resulted in the development of an efficient Air Circulation Unit