Abstract

This document explains the calibration procedure adopted to test the pitot-static probes, as required by HAL, Koraput . These probes (16 n.o)s were calibrated in the 254 min x 102 mm induction tunnel of the Aerodynamics Division of the Laboratory . The probe calibration factor were determined and tabulated as shown

Item Type: Monograph (Project Report)
Uncontrolled Keywords: Probe Calibration, Pitot-static probes, Propulsion systems