Raghuram, AC and Radhakrishnan, S and Ramachandran, V (1985) Failure of a reheat fuel pump. Project Report. National Aerospace Laboratories, Bangalore.
![]() | There is a more recent version of this item available. |
![]() |
PDF
PD_MT_8522.pdf Download (61kB) |
Abstract
The failure of a reheat fuel pump was analysed. The roller bearing and the light alloy cage had been badly damaged. Dimensional differences in the component assembly caused relative displacement of the inner race, cage and the rolling elements with respect to the outer race. This in turn caused the failure of the roller bearing and cage.
Item Type: | Monograph (Project Report) |
---|---|
Uncontrolled Keywords: | Reheat fuel pump;Roller bearing;Cage;Race |
Subjects: | CHEMISTRY AND MATERIALS > Chemistry and Materials (General) |