Krishna Kumar, VS and Jagannatha Rao, B and Chidananda, MS (1987) Calibration of flowmeters Jaguar Project (H.A.L)BANGALORE. Project Report. National Aerospace Laboratories, Bangalore.
![]() |
PDF
PD_PR_8702.pdf - Published Version Download (63kB) |
Abstract
This document describes flow the recalibration tests' carried out on the fuel meters employed for evaluation of fuel transfer pumps of the 'engines' fitted to the Jaguar Aircraft at the final assembly shop in Aircrafts Division of the Hindustan Aeronautics Ltd., Bangalore. The results of the calibration tests are tabulated and also shown graghically.
Item Type: | Monograph (Project Report) |
---|---|
Uncontrolled Keywords: | Fuel Flow Calibration Flow Metering |
Subjects: | AERONAUTICS > Aircraft Propulsion and Power |
Depositing User: | Ms Indrani V |
Date Deposited: | 23 Aug 2012 07:59 |
Last Modified: | 23 Aug 2012 07:59 |
URI: | http://nal-ir.nal.res.in/id/eprint/10841 |
Actions (login required)
![]() |
View Item |