Rao, RMVGK and Padma, A and Vishnubhat, and Rajendra Prakash, M and Kavitha, and Vanaja, A (1996) Comparative Evaluation of different Resin Batches used in HANSA-3 (old Vs-New Batches). Project Report. National Aerospace Laboratories, Bangalore.
![]() |
PDF
PD_MT_9618.pdf - Published Version Download (411kB) |
Abstract
The properties of the resin system used as matrix for composites are important sin& the mechanical strength and fabrication processes of the components depend on these prdpenies. Hence it was considered essential to monitor the properties of the resins during their storage for a long period of time. A number of resin batches were earlier received in mid 1994 for use in HANSA - 3 component fabrication. Subsiquently a new batch of LY 5052 resin and the corresponding HY 5052 hardener were obtained through HAL, as a replacement stock in Feb 96 which had to be used to complete the fabrication of HANSA-3 components after the properties were monitored. As per the HANSA -3 cornittee advice a comparative evaluation of those two batches (old & new) of resins was made.
Item Type: | Monograph (Project Report) |
---|---|
Uncontrolled Keywords: | Resin, Reinforcement, Test Laminate, Test Specimen, Gel Time Exotherm |