Analysis of failed rubberized fuel tank

Parameswara, MA and Venkataswamy, MA and Madan, M and Sujata, M and Suresh Kumar, M and Bhaumik, SK (2005) Analysis of failed rubberized fuel tank. Project Report. National Aerospace Laboratories, Bangalore.

Full text not available from this repository. (Request a copy)

Abstract

The rubberized fuel tank was found to have failed in the collar band regions. The failure was by tensile tearing along the line joining the mounting holes. It appears most probable that improper tightening of the mounting brackets and/or nonconformities in the dimension of the rubberized fuel tank would have resulted in the tensile load in the mounting holes. No material abnormalities appear to be responsible for the failure.

Item Type: Proj.Doc/Technical Report (Project Report)
Uncontrolled Keywords: Rubberized fuel tank, improper assembly/dimension