Failure analysis of cyclic-stick of a helicopter

Madan, M and Venkataswamy, MA and Sujata, M and Bhaumik, SK (2007) Failure analysis of cyclic-stick of a helicopter. Project Report. National Aerospace Laboratories, Bangalore, India.

Full text not available from this repository. (Request a copy)

Abstract

The detachment of the cyclic-stick of the helicopter was due to fracturing of the cast Mg-alloy socket. The socket had failed by static overload. Evidences suggest that the cyclic-stick had experienced sudden impact load in a direction away from the pilot leading to the failure of the socket. There were no evidences of progressive failure such as fatigue. Also, no metallurgical or mechanical abnormalities were responsible for the failure. A detailed analysis of the failure is presented in this report.

Item Type: Proj.Doc/Technical Report (Project Report)
Uncontrolled Keywords: Civil aviation;Helicopter;Cyclic-stick;Overload
Subjects: AERONAUTICS > Aeronautics (General)
CHEMISTRY AND MATERIALS > Chemistry and Materials (General)
Division/Department: Materials Science Division, Materials Science Division, Materials Science Division, Materials Science Division
Depositing User: Ms. Alphones Mary
Date Deposited: 26 Jul 2011 16:45
Last Modified: 26 Jul 2011 16:45