Failure analysis of clogging indicator

Suresh Kumar, M and Madan, M and Venkataswamy, MA and Sujata, M and Bhaumik, SK (2006) Failure analysis of clogging indicator. Project Report. National Aerospace Laboratories, Bangalore.

Full text not available from this repository. (Request a copy)

Abstract

In continuation of the investigation carried out earlier on the failure of clogging indicator of high-pressure filter in EDP line of an aircraft, the separation membrane of another clogging indicator used in the same aircraft at the same location removed during its 100 hr servicing was sent to the laboratory for examination. Observation revealed that the membrane had damages similar to that reported earlier. The damages were found to have been caused due to repeated impact of the magnets on the separation membrane surfaces. Whether or not these damages were caused due to abnormalities in assembly and/or functioning need to be established.

Item Type: Proj.Doc/Technical Report (Project Report)
Uncontrolled Keywords: Aircraft; clogging indicator; separation membrane; impact damages
Subjects: AERONAUTICS > Aeronautics (General)
CHEMISTRY AND MATERIALS > Chemistry and Materials (General)
Division/Department: Materials Science Division, Materials Science Division, Materials Science Division, Materials Science Division, Materials Science Division
Depositing User: Raghavendra R chandu
Date Deposited: 25 Jul 2011 11:14
Last Modified: 25 Jul 2011 11:14