Analysis of failed loop condenser tube

Rangaraju, R and Bhaskaran, TA and Venkataswamy, MA and Keshab, Barai and Bhaumik, SK (2003) Analysis of failed loop condenser tube. Project Report. National Aerospace Laboratories, Bangalore.

Full text not available from this repository. (Request a copy)

Abstract

Failed tube samples taken from 1524 Loop Cooler Condenser of synthesis plant at SPIC, Tuticorin were sent to the laboratory for investigation. Samples from unfailed tubes were also provided for comparative study. Examination revealed two basic mechanisms, viz., hydrogen embrittlement and fatigue as the cause of fracture/cracking of the tubes. However, with the available data, it was not possible to establish which mechanism took precedence over the other.

Item Type: Proj.Doc/Technical Report (Project Report)
Uncontrolled Keywords: Condenser cooler tube;hydrogen embrittlement;fatigue
Subjects: AERONAUTICS > Aeronautics (General)
CHEMISTRY AND MATERIALS > Chemistry and Materials (General)
Division/Department: Materials Science Division, Materials Science Division, Materials Science Division, Materials Science Division, Materials Science Division
Depositing User: Mrs Manoranjitha M D
Date Deposited: 14 Jul 2011 16:32
Last Modified: 14 Jul 2011 16:32
URI: http://nal-ir.nal.res.in/id/eprint/9375