Venkataswamy, MA and Sujata, M and Keshab, Barai and Bhaumik, SK (2003) Analysis of fractured JOHNSON SCREEN of HPNA absorption chamber. Project Report. National Aerospace Laboratories, Bangalore.
Full text not available from this repository. (Request a copy)Abstract
A failed Johnson screen was sent to the laboratory for analysis. The screen was found to have failed at the flange hub – screen joint. Analysis showed that the failure was due to inadequate welding of the flange hub with the ribs/stiffeners of the screen. The failure was by sudden overload. There were no indications of delayed failure like fatigue or stress corrosion cracking. Semi-quantitative analysis by EDX showed that the helical coil of the screen was made of SS 304 steel while the ribs/stiffener were made of SS 316 steel.
| Item Type: | Proj.Doc/Technical Report (Project Report) |
|---|---|
| Uncontrolled Keywords: | Johnson screen;welding;overload failure |
| Subjects: | CHEMISTRY AND MATERIALS > Chemistry and Materials (General) |
| Division/Department: | Materials Science Division, Materials Science Division, Materials Science Division, Materials Science Division |
| Depositing User: | Mrs Manoranjitha M D |
| Date Deposited: | 07 Jul 2011 14:56 |