CALIBRATION OF PITOT STATIC PROBES FOR HAL, KORAPUT

Sharath, PP and Senthil Kumaran, R and Jagannatha Rao, B and Poornima, N (2009) CALIBRATION OF PITOT STATIC PROBES FOR HAL, KORAPUT. Technical Report. National Aerospace Laboratories, Bangalore.

Full text available as:
[img] PDF - Submitted Version
Download (177Kb)

    Abstract

    This document furnishes the calibration procedure adopted to test some of the Pitot static probes used by HAL, Koraput in their engine test beds. Twenty eight probes were sent to NAL for calibration and certification. These probes were calibrated in the 254 mm x 102 mm induction wind tunnel at NAL. The probes were calibrated for a Mach number range of 0.1 to 0.4.

    Item Type: Proj.Doc/Technical Report (Technical Report)
    Subjects: AERONAUTICS > Aerodynamics
    AERONAUTICS > Research and Support Facilities (Air)
    ENGINEERING > Fluid Mechanics and Thermodynamics
    PHYSICS
    Division/Department: Propulsion Division, Propulsion Division, Propulsion Division, Propulsion Division
    Depositing User: Mr R Senthil Kumaran
    Date Deposited: 05 Aug 2010 13:17
    Last Modified: 05 Aug 2010 13:17
    URI: http://nal-ir.nal.res.in/id/eprint/8896