Description and calibration of the 2quot;x10quot; induction tunnel (with and without plenum chamber suction)

Sundaramurthy, H and Gurjale, AK and Gopala, KV (1971) Description and calibration of the 2quot;x10quot; induction tunnel (with and without plenum chamber suction). Technical Report. National Aeronautical Laboratory, Bangalore, India.

Full text available as:
[img] PDF
Restricted to Archive staff only

Download (951Kb)

    Abstract

    Tests were conducted for the calibration of the 2quot; x 10quot; Induction Tunnel. The set-up for plenum chamber suction was completed and tried out for the first time. Results of calibration tests are presented along with a brief description of the various components of the tunnel.13; The results show that test section Mach numbers upto 0.92 can be obtained with the operation of main injector, and Mach number distribution in the test section between station1 and 15 is within 4- .005 for a wall divergence angle 6w= 1.25xB0;. With auxiliary suction, Mach numbers upto 1.18 are obtained in the test section; for this range, the maximum variation from the mean Mach number is _+ .01 between statiors3 and 13 in the test section. The boundary layer thickness on each of the side walls at the test section is about 10% of the span, for all Mach numbers.

    Item Type: Proj.Doc/Technical Report (Technical Report)
    Uncontrolled Keywords: Induction tunnel;Calibration;Suction;Components,Injector
    Subjects: AERONAUTICS > Aerodynamics
    Division/Department: Aerodynamics, Aerodynamics, Aerodynamics
    Depositing User: M/S ICAST NAL
    Date Deposited: 08 Dec 2006
    Last Modified: 24 May 2010 09:53
    URI: http://nal-ir.nal.res.in/id/eprint/3579