Kalyanam, M and Bose, TK (1967) Design characteristics of an electrostatic Langmuir for nitrogen plasma. Technical Report. National Aeronautical Laboratory, Bangalore, India.
Full text available as:| PDF Restricted to Archive staff only Download (954Kb) |
Abstract
Current-voltage characteristic curve for Langmuir probe was completed for a real gas like nitrogen plasma. Preliminary calculations were made to determine13; the Debye shielding length and different mean free paths for nitrogen plasma. Depending on the values of these quantities, the Child-Langmuir law and the diffusion theory were applied to determine the characteristic curve at different voltage ranges, where one or other theory is only applicable. Specification of the proposed probe to be fabricated in NAL is discussed.
| Item Type: | Proj.Doc/Technical Report (Technical Report) |
|---|---|
| Uncontrolled Keywords: | Design characteristics;Electrostatic languisher;Nitrogen plasma |
| Subjects: | CHEMISTRY AND MATERIALS > Chemistry and Materials (General) |
| Division/Department: | Materials Science Division, Materials Science Division |
| Depositing User: | M/S ICAST NAL |
| Date Deposited: | 09 Nov 2006 |
| Last Modified: | 24 May 2010 09:53 |
| URI: | http://nal-ir.nal.res.in/id/eprint/3346 |
Actions (login required)