Pureswaran, Shankar and Santhanam, A (1974) Instrumentation for fluidic temperature sensor. Technical Report. National Aeronautical Laboratory, Bangalore, India.
Full text available as:| PDF Restricted to Archive staff only Download (962Kb) |
Abstract
An instrumentation system for the measurement of high temperatures using a fluidic sensor,its calibration and application is discussed in this report.Experimental investigations using this instrumentation set-up for the detection of simulated reheat on/off in after burned and their results are presented.The results indicate that reheat on/off sensor based on fluidic oscillator can be built by incorporating certain improvements in electronic logic design so as to monitor rate of rise and fall in temperature.
| Item Type: | Proj.Doc/Technical Report (Technical Report) |
|---|---|
| Uncontrolled Keywords: | Fluidic sensor;Reheat on/off sensor;Fluidic oscillator |
| Subjects: | AERONAUTICS > Aerodynamics |
| Division/Department: | Propulsion Division, Propulsion Division |
| Depositing User: | M/S ICAST NAL |
| Date Deposited: | 07 Nov 2006 |
| Last Modified: | 24 May 2010 09:53 |
| URI: | http://nal-ir.nal.res.in/id/eprint/3324 |
Actions (login required)