Instrumentation for fluidic temperature sensor

Pureswaran, Shankar and Santhanam, A (1974) Instrumentation for fluidic temperature sensor. Technical Report. National Aeronautical Laboratory, Bangalore, India.

[img] PDF
Restricted to Repository staff only

Download (985kB)


An instrumentation system for the measurement of high temperatures using a fluidic sensor,its calibration and application is discussed in this report.Experimental investigations using this instrumentation set-up for the detection of simulated reheat on/off in after burned and their results are presented.The results indicate that reheat on/off sensor based on fluidic oscillator can be built by incorporating certain improvements in electronic logic design so as to monitor rate of rise and fall in temperature.

Item Type: Monograph (Technical Report)
Uncontrolled Keywords: Fluidic sensor;Reheat on/off sensor;Fluidic oscillator
Subjects: AERONAUTICS > Aerodynamics
Depositing User: M/S ICAST NAL
Date Deposited: 07 Nov 2006
Last Modified: 24 May 2010 04:23