Vijayan, Kalyani and Mani, A and Balasingh, C and Singh, AK (1987) X-ray analysis of polycrystalline aluminium subjected to fatigue cycling. Technical Report. National Aeronautical Laboratory, Bangalore, India.
Full text available as:| PDF Restricted to Archive staff only Download (7Mb) |
Abstract
Variations in the halfwidth values of x-ray reflections from fatigue cycled, polycrystalline aluminium samples have been analysed. A hitherto 'unknown oscillatory distribution of the (bib) values with fatigue cycling has been observed. The present data also indicate that (i) the broadening due to fatigue cycling increases with increase in glancing angle (ii) the changes in the halfwidth and the integral width values due to fatigue cycling are comparable and (iii) the (bib) vs N curves for fatigue cycling under constant stress amplitude and under flight loading conditions are comparable.
| Item Type: | Proj.Doc/Technical Report (Technical Report) |
|---|---|
| Uncontrolled Keywords: | Fatigue cycling;X-ray analysis;Oscillatory distribution;13; Microstrain |
| Subjects: | CHEMISTRY AND MATERIALS > Composite Materials CHEMISTRY AND MATERIALS > Chemistry and Materials (General) |
| Division/Department: | Materials Science Division, Materials Science Division, Materials Science Division, Materials Science Division |
| Depositing User: | M/S ICAST NAL |
| Date Deposited: | 02 Nov 2006 |
| Last Modified: | 24 May 2010 09:52 |
| URI: | http://nal-ir.nal.res.in/id/eprint/3125 |
Actions (login required)
| View Item |