Nagpurwala, QH (1988) Recovery characteristics of three shielded thermocouple13; temperature probes. Technical Report. National Aeronautical Laboratory, Bangalore, India.
Full text available as:| PDF Restricted to Archive staff only Download (6Mb) |
Abstract
This report presents the recovery characteristics of13; thermocouple temperature probes having three different shield configurations. Tests were conducted in a 0.25 m x 0.1 m cross-section Induction Tunnel over a subsonic Mach number range of 0.1 lt; M lt; 0.65 and a yaw angle range of -300 0lt;:lt;+30xB0; under atmospheric total pressure conditions. Results indicate that the recovery factors and recovery ratios of cylindrical probes are much lower at all Mach numbers and show very poor reproducibility compared to the half shielded and Kiel type probes. However, the output of the half shielded probe is found to be more sensitive to yaw angle compared to the other two probes. Recovery data of an unshielded thermocouple probe are also presented for reference.
| Item Type: | Proj.Doc/Technical Report (Technical Report) |
|---|---|
| Uncontrolled Keywords: | Temperature probes;Recovery characteristics |
| Subjects: | AERONAUTICS > Aircraft Propulsion and Power |
| Division/Department: | Propulsion Division |
| Depositing User: | Deputy Head Poornima Narayana |
| Date Deposited: | 17 Aug 2006 |
| Last Modified: | 24 May 2010 09:45 |
| URI: | http://nal-ir.nal.res.in/id/eprint/2091 |
Actions (login required)
| View Item |