Sundaram, S (1989) Calibration of vane anemometer. Technical Report. National Aeronautical Laboratory, Bangalore, India.
Full text available as:| PDF Restricted to Archive staff only Download (2179Kb) |
Abstract
The calibration of the 'Vane Type Anemometer' used for Industrial applications was made using a digital micromamometer in the low turbulence, low speed wind tunnel in the speed range specified (3m/s to 18m/s) The given instrument was found to be reading with in an accuracy of 3 in the specified range.