Brahma, KK (1996) Seismic Qualification Testing of 300 AH RPC / H C P LM Cells on Steel Stand. Technical Report. National Aerospace Laboratories, Bangalore, India.
Full text available as:| PDF Restricted to Archive staff only Download (4Mb) |
Abstract
This report contains the results of the seismic qualification tests performed on13; 300 AH RPG/IMP LM cells on steel stand for M/s Standard Batteries Ltd.,13; Bombay. The seismic qualification tests, as approved by Nuclear Power13; Corporation (NPC), Bombay were carried out at the Shake Table Facility at13; Structural Integrity Division (SID) of National Aerospace Laboratories13; (NAL), Bangalore. While tests were carried out by the stall of the Division,13; the represetatives of M/s SBL were involved in monitoring electrical13; performance of 300AH RPC/HDP LM cells, such as terminal voltage13; across the cell and discharge current, during the test. These tests were witnessed13; by the representatives of M/s SBL and their user, NPC, Bombay. This test13; report constitutes a part of the necessary seismic qualification and is intended13; to be supplemented by M/s SBL , Bombay to form a full Qualification13; document.13; 13;