    Abstract

    This report contains the results of the seismic qualifications tests performed on 250 V DC, 100 kW, Soft Starter Panel for M/s Innovative Technomics Private Limited, Pune. The seismic qualification tests, as13; approved by Nuclear Power Corporation (NPC), Mumbai were performed in the shake table facility available in Structural Integrity Division (SID) of National Aerospace Laboratories (NAL), Bangalore. While the staff of the13; Division carried out tests, the representatives of M/s ITPL were involved in monitoring functional parameters of soft starter during the test. The representative of M/s ITPL and OS office of NPC, Bangalore, witnessed13; these tests. This report constitutes the final seismic qualification documentation for the user.

    Item Type: Proj.Doc/Technical Report (Technical Report)
    Uncontrolled Keywords: Seismic qualification testing;IEEE-344-1987 standards;Soft Starter Panel
    Subjects: ENGINEERING > Structural Mechanics