Kumar, Rajeev and Sundaram, S (2000) Refurbishment and calibration studies of 0.3m water tunnel facility13; 13;. Technical Report. National Aerospace Laboratories, Bangalore, India.
Full text available as:| PDF Restricted to Archive staff only Download (2908Kb) |
Abstract
An open circuit, gravity driven water tunnel was refurbished and made13; operational recently . The components refurbished included a storage tank with13; built-in bell mouth section, a smooth contraction and a flow conditioner unit . With13; these new components, the flow quality of the tunnel improved substantially and13; steady flow can now be achieved up to about 6 cm/s as compared to the (max .)13; velocity of about I cm/s before refurbishment . This report contains a description13; of the refurbished water tunnel and its calibration .
| Item Type: | Proj.Doc/Technical Report (Technical Report) |
|---|---|
| Uncontrolled Keywords: | Water tunnel;Honeycomb;Screens;Flow visualization;Delta wing;13; Reynolds Number;Flow separation;Vortex breakdown . |
| Subjects: | AERONAUTICS > Aerodynamics |
| Division/Department: | Experimental Aerodynamics Division, Experimental Aerodynamics Division |
| Depositing User: | Mrs Manoranjitha M D |
| Date Deposited: | 21 Apr 2006 |
| Last Modified: | 24 May 2010 09:40 |
| URI: | http://nal-ir.nal.res.in/id/eprint/1210 |
Actions (login required)