Calibration of pitot static probes for HAL- Bangalore

Jagannatha Rao, B and Venkatesh, S and Chidananda, MS (1988) Calibration of pitot static probes for HAL- Bangalore. Project Report. National Aerospace Laboratories, Bangalore.

Full text available as:
[img] PDF - Published Version
Download (60Kb)

    Abstract

    This document explains the calibration procedure adopted to test the pitot-static probes, as reqpired by HAL, B'lore . These probes (4 nos) were oalibrajed in the 254 nom x 102 mm induction tunnel of the Aerodynamics Division of the laborstort' The probe calibration factors were deteradned and tabulated as shown.

    Item Type: Proj.Doc/Technical Report (Project Report)
    Uncontrolled Keywords: Probe calibration, pitot-static probes, Propulsion systems
    Subjects: AERONAUTICS > Aircraft Propulsion and Power
    Division/Department: Propulsion Division, Advanced Composites Division, Propulsion Division
    Depositing User: Ms Indrani V
    Date Deposited: 09 Oct 2012 13:59
    Last Modified: 09 Oct 2012 13:59
    URI: http://nal-ir.nal.res.in/id/eprint/11072

    Actions (login required)

    View Item