Calibration Of Pitot Rakes (Rectangular Cross Section) At Selected Transonic Mach Numbers

Narasimhaswamy, KN (1990) Calibration Of Pitot Rakes (Rectangular Cross Section) At Selected Transonic Mach Numbers. Technical Report. NAL, Bangalore.

Full text available as:
[img] PDF
Download (55Kb)

    Abstract

    On The Request Of Gas Turbine Research Establishment, Bangalore, National Aeronautical Laboratory Undertook Calibration Of Several Of Their Pitot Rakes, Which Are Used In Flow Measurements In Test Compressors., In This Report, Results Of Pressure Recovery On Four Pitot Rakes At Selected Transonic Mach Numbers Are Presented.

    Item Type: Proj.Doc/Technical Report (Technical Report)
    Uncontrolled Keywords: Calibration Of Pitot Rakes; Pressure Recovery Of Probes In Transonic Flows
    Subjects: AERONAUTICS > Aeronautics (General)
    Division/Department: Wind Energy Programme
    Depositing User: M/S ICAST NAL
    Date Deposited: 21 Sep 2012 11:07
    Last Modified: 21 Sep 2012 11:07
    URI: http://nal-ir.nal.res.in/id/eprint/10975

    Actions (login required)

    View Item