Flow Visualisation Studies On Wall Mounted Pitot Type Intake With Splitter Plate

Ramaswamy, MA and Narasimhaswamy, KN (1991) Flow Visualisation Studies On Wall Mounted Pitot Type Intake With Splitter Plate. Technical Report. NAL, Bangalore.

[img] PDF
PD_EA_9112.pdf

Download (69kB)

Abstract

Flow Visualisation Studies Employing Schlieren/Shadowgraph Technique And -Simple Oil Flow Technique Were Carried Out On A Simple Pitot Type Of 1-Btake With Splitter Plate Mounted On Base Plate In The NAL 0 .3m Tunnel . Between The Splitter Plate And The Base Plate, A Heat Exchanger Duct With Wedge Diverters Was Also Simulated . From These Studies, The Effect Of Closure Of The Intake Duct And The Heat Exchanger Duct On The Flow Behaviour Was Qualitatively Determined . It Was Found That Flow Constraint In The Heat Exchanger Duct And Diverter Passages Had Considerable Effect On The Flow Through The Intake.

Item Type: Monograph (Technical Report)
Uncontrolled Keywords: Intake Flows;Flow Visualisation
Subjects: AERONAUTICS > Aeronautics (General)
Depositing User: Users 90 not found.
Date Deposited: 03 Dec 2012 05:54
Last Modified: 03 Dec 2012 05:54
URI: http://nal-ir.nal.res.in/id/eprint/10923

Actions (login required)

View Item View Item