Calibration of pi tot-static probes for H.A.L., Koraput

Jagannatha Rao, B and Krishna Kumar, VS and Chidananda, MS (1988) Calibration of pi tot-static probes for H.A.L., Koraput. Project Report. National Aerospace Laboratories, Bangalore.

Full text available as:
[img] PDF - Published Version
Download (86Kb)

    Abstract

    This document explains the calibration procedure adopted 4 to test the pitot-static probes, as required by H .A .L ., Koraput. These probes (12 Nos .) were calibrated in the 254 mm x 102 mm induction tunnel of the Aerodynamics Division of the Laboratory. The probe calibration factors were determined and tabulated as shown.

    Item Type: Proj.Doc/Technical Report (Project Report)
    Uncontrolled Keywords: Probe calibration, Pitot-static probes, Propulsion systems
    Subjects: AERONAUTICS > Aircraft Propulsion and Power
    Division/Department: Propulsion Division, Propulsion Division, Propulsion Division
    Depositing User: Ms Indrani V
    Date Deposited: 27 Aug 2012 09:49
    Last Modified: 27 Aug 2012 09:49
    URI: http://nal-ir.nal.res.in/id/eprint/10853

    Actions (login required)