Jagannatha Rao, B and Krishna Kumar, VS and Chidananda, MS (1988) Calibration of pi tot-static probes for H.A.L., Koraput. Project Report. National Aerospace Laboratories, Bangalore.
Full text available as:| PDF - Published Version Download (86Kb) |
Abstract
This document explains the calibration procedure adopted 4 to test the pitot-static probes, as required by H .A .L ., Koraput. These probes (12 Nos .) were calibrated in the 254 mm x 102 mm induction tunnel of the Aerodynamics Division of the Laboratory. The probe calibration factors were determined and tabulated as shown.
| Item Type: | Proj.Doc/Technical Report (Project Report) |
|---|---|
| Uncontrolled Keywords: | Probe calibration, Pitot-static probes, Propulsion systems |
| Subjects: | AERONAUTICS > Aircraft Propulsion and Power |
| Division/Department: | Propulsion Division, Propulsion Division, Propulsion Division |
| Depositing User: | Ms Indrani V |
| Date Deposited: | 27 Aug 2012 09:49 |
| Last Modified: | 27 Aug 2012 09:49 |
| URI: | http://nal-ir.nal.res.in/id/eprint/10853 |
Actions (login required)
| View Item |